  1. buitenhek

    EMI Measurement

    great suggestion ironhorse17 and great call out TR. Facilities versus an RCDD on a network related issue. Classic bean counter $direction. Spend thousands on servers, routers and computers for very high paid people and install on the cheap. EMI problem diagnosis is a bear. Could go into the...
  2. buitenhek

    Cat 5e plenum price per drop

    My material cost is a little better than the average bear, so your pricing should reflect your quoted rates. 200-V2D average cost is $158/drop and sell average at $225/drop 60,000' CAT6 plenum cable, 600 CAT6 jacks, 80 hangers, 260 J-hooks, 200 faceplates/mudrings, 300 hours. 6-96 port CAT6...
  3. buitenhek

    wire gauge for jhooks

    a 4" J-hook can hold 250+ cables Regards Peter Buitenhek Director BidQwik.com ProfitDeveloper.com "Never settle for a job well done...always look for cost cutting measures
  4. buitenhek

    One 4 Pair Cat5 for two devices?

    Firefoxfire The old timers & gurus in this group know it would work but are also smart enough to not say anything or try and talk you out of it. If (when) there is a problem later, it always seems to come back to the exception. Example Auto-lube company wanted remote computer and only had 1...
  5. buitenhek

    Manager team relationship

    1. Personal issues should be separate from work related discussions 2. clearly define deliverables and objectives that need to be met by employee 3, with Item #2 defined, performance discussions against those D/O will be obvious and simple to measure Regards Peter Buitenhek Director BidQwik.com...
  6. buitenhek

    Untwisted Cat5e cable causing problems?

    hold up the CAT5 cable end with the jack. Look at the CAT5 jack with the clip facing back. Note the color of the solid cables connecting to the jack from left to right. Match that same color pattern (left to right) on your far side CAT5 jack. Regards Peter Buitenhek ProfitDeveloper.com "Never...
  7. buitenhek

    Per Drop Testing Cost???

    Usually plenum or PVC in conduit, CAT5e, tricky installs (trailer, trenching, poles), prevailing wage, technicians fingerprinted (your cost). Take your usual cost per drop of voice/data and multiply by 1.2 to 1.5. If you are a little more specific on what you need it might be easier to "hazard"...
  8. buitenhek

    Horizontal Cabling Percentage & Pricing

    Obviously there are also economies of scale. One drop is more expensive than averaging 36 drops if you include hangers and panels/blocks/management. Each project will be slightly different depending on the cable arrangement/hangers etc)but...on average: 1. 1 CAT6e cable (no hangers) Pull cable...
  9. buitenhek

    Horizontal Cabling Percentage & Pricing

    I am putting together a spreadsheet and wanted to get a general feel from the forum on some values you have seen in your market for typical pvc voice/data/fiber installs. Thank you for the effort. Labor Percent of Total Bid Sell Price 40% Material Percent of Total Bid Sell Price 60%...
  10. buitenhek

    Shielded Twisted Pair Without Ground?

    Robhub is correct about the antenna effect. But using STP for a typical UTP app may still work fine. 1. Do not ground either end, cut back foil but leave twist intact 2. Run a cable (in ceiling or on floor) to near max limit of 100 meters. Remember patch cords will be hooked at both ends. 3...
  11. buitenhek

    How do I trace cables without disrupting service?

    Disconnect 10 cables at the hub every 10 minutes and see who calls to complain. WhaLa...site map. Just kidding, I like jimbopalmer's free solution. By the way, I am certain many of the experts here wanted to say the same as my boob answer but had too much class to do so. Happy New Year ad omnis...
  12. buitenhek

    Comm. Closet Ventilation

    In my short 29 years cabling experience, stuff happens after 87 degrees continuous. Think and grow rich. Regards Peter Buitenhek ProfitDeveloper.com "Never settle for a job well done...always look for cost cutting measures
  13. buitenhek

    Raceway???

    Serva and Syq are correct. You can run your own grid wires but you cannot use the existing ceiling grid, ever. Regards Peter Buitenhek ProfitDeveloper.com "Never settle for a job well done...always look for cost cutting measures
  14. buitenhek

    Cat 6 and Cat6A distance

    If it passes the cable tester for the network they want to install, the distance passes. Regards Peter Buitenhek ProfitDeveloper.com "Never settle for a job well done...always look for cost cutting measures
  15. buitenhek

    How long it takes to pull a cable...

    Cosmo, I agree with recoa01 at 1.75 hrs per 3 cable (2 CAT6, 1CAT3). But remember there are economies of scale involved. Assume 30 pulls/term/doc of 3 cables the labor time might be around 48 hours or about 1.6 hrs each and 300 p/t/d might be around 420 hours or 1.4 hrs each. (note: estimates...