All good points above, I am glad I am not doing paging anymore but I did prefer Bogen.
We used to use 1/4 watt setting for most quite applications (office, department stores) and all single home run cables!
If I recall, Valcom uses 2 pairs per speaker, power and audio, so an Amp and a separate...
Thanks for that refresher/reply.
I do not see a way to disable DHCP on these switches so I assumed they do not handle DHCP, instead they rely on the main equipment to handle DHCP.
The only DHCP is for the IP address itself, I assigned Static to both but I see that one unit did not take so they...
I have an issue with IP Conflict.
'arp -a' shows that both my BES50's (in my own office) are showing 2 IP's each with the same MAC address
192.168.1.226 (via DHCP)
192.168.1.0
My modem is 192.168.1.1
Range is set to 192.168.1.2 - 253
'arp -a' only shows one 192.168.1.0, but I...
Sorry, we vendors, techs and clients do not charge in this forum.
The same would be with the other top telecom forum.
If you want to help a service company then you need to contact them direct, but in both cases your a little late to the party thanks to "hosted" off site solutions.
The Nortel...
"Is there anyway to use the Element manager in win11 for BCM400?"
Only for release 4.0, all previous versions are programmed with web browser only
Yes to Win 10 or 11
62.03 was the last regular version, 62.04 and 62.05 were temp fixes for certain issues.
Still, you can use anyone.
Make sure...
Solved!
Sets are IP phones and 1 backup digital phone at reception in case of network failure.
Mr ramblingrebel went to site and resolved it.
The digital phone does have lines assigned as A&R but is set to DND mode until such event occurs.
The issue was that somebody mistakenly turned off DND...
Check reception set, make sure the Target line/s is told "Appear Only" and not "Appear & Ring" or "Ring Only"
It rings the set based on Appear & Ring then CP quickly grabs it hence the ring splash.
Feature *85 is to only enter/activate or change the password
To deactivate the admin does that to protect your phone.
It's in Administration programming.
Under Passwords/CallLogPasswords/Enter DN/Ext # then press clear.
If you are a user then contact your site admin to program as they would...
You relocated the main door phone off the MBM, so was there issues with all or just the other 3?
How often does it happen? daily? weekly?
You need to have those relays disconnected be it just for testing, or a few days or depending how often the issue occurs.
Maybe disconnect one door phone...
I found this guide: Total Access 900e Series Hardware Installation Guide
Page 2:
Software Licensing Agreement
Each ADTRAN product contains a single license for ADTRAN-supplied software. Pursuant to the
Licensing Agreement, you may: (a) use the software on the purchased ADTRAN device only and...
I don't see that....but it would make sense.
Have you read the guide?
I am guessing the guide would tell you the pre-requisites right at the begging so that you know what you need before installation.
Sounds like relay's on the DOC going to Crestron system to activate camera's.
Since the all go to the Crestron then there is a loop, perhaps remove the relay wires on one door phone (at a time), test for a few days or until it proves the others are still having the issue. If after removing each...