Alarm code: 73
Reset:
No
Description:
Timing has been lost on T1 or BRI. CSU is freerunning.
Action:
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from Nov-April
swap to determine if its extender
if yes-return/replace
if no-reterm fiber
could also check station module
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from Nov-April
Tried to reset with f985 then 9..nothing...tried 7 and it asked for password..tried the reset password and nothing.
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from Nov-April
The DB loss from telco "copper" plus the DB loss from MICS usually will be 7 or 8
+/- a couple depending on telco "and telco is usually within it limits"
Either go to a T1 or live with it.
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from...
AGREE WITH silver987 compatibility was rarely a drop dead issue just some minor glitches.Also could be that expensive for 2.1 flash software
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from Nov-April
if u have newer version of software you should be able to us routing with overflow when the 3 lines are in use "if your talking about outbound calls". Inbound is your provider on hunt.
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from Nov-April
Are they home runs to the ksu or out to a IDF ?If you tone cables do you get tone on both station cables?
If the above 2 are not the problem make sure autoset relocation is off then reboot ksu.
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from...
Says just option switches
http://supportdocs.polycom.com/PolycomService/support/global/documents/support/user/products/voice/soundstation2_direct_connect_nortel_user_guide.pdf
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from Nov-April
if 210 has FNA ..201 must have fna set lower..so if its 4 on 210 ..201 must be 3 or lower
also if 201 "ata" has line appearance check AA
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from Nov-April
thinkin Arc4967 is on other side of the pond
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from Nov-April
Try refreshing port with a different set as in 7100 or 7208 then after that comes up plug back in and reprogram the 7324 and see if that works.
Also if swapping ports do not use autoset relocation
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski...
is it a t1 in your switch...Are u sure you have your trunks programmed correctly for you t1?
is telco supplying received digits on inbound call or are they just ringing in in a sequential order on the individual trunks
Is it a breakout for dialtone going into analog trunk cartridge..if so...
When there is a pissing contest on a t1/pri and YOU dont have a tberd, YOU get pissed on
Pretty much retired from telecom and now grow and sell perennials from April-November and Ski from Nov-April