Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Chriss Miller on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by vegasnortel

  1. vegasnortel

    CP150 Call Monitoring "Beeps" Need fix!

    thanks to all who replied...especially telemarv who replied in a direct email. I found that you need to go top Feature settings in the MICS where MOH, set relocation, etc.... is located and turn SM to "Y" to work properly on the CP150. As soon as I did and tested, the beep went away. Kind of...
  2. vegasnortel

    CP150 Call Monitoring "Beeps" Need fix!

    He has a button programmed for F905 that is uused. He is using 7.1XC on MICS and 31.10.14.22 on CP150. The feature when invoked is truly silent unless Supervisor elects to "Join", but he never would. Although still silent, all parties....Agent, Spervisor, and Caller hear the distinctive "beep"...
  3. vegasnortel

    CP150 Call Monitoring "Beeps" Need fix!

    MICS is 7.1XC and CP150 is 3.1 with I beleive latest release. Enabled for 50 Agents, 20 Skillsets, 48 MB's, Advanced Call Center. The beeping clearly contradicts the official Nortel docs in Supervisors manual based on CP150 3.0.
  4. vegasnortel

    CP150 Call Monitoring "Beeps" Need fix!

    I have a cleint on MICS 7.1, CP150 w/ Enhanced Call Center. They mostly dial outbound and I have all Agents setup so Supervisor can login and monitor calls. the problme is that when he uses F905 and selects agent to monitor, there is a distinctive "Beep" when he begins and ends monitoring. This...
  5. vegasnortel

    Call Forward to cell Phone

    What is the stepps to program the system (nortel software 6.1) to forward to cell phone. Right now only can forward to internal extention. (all lines are analoge) Thanks
  6. vegasnortel

    Conduit size recommendations

    Thanks all! The conduit fill Table is perfect! I think we may be pulling 2 cables instead of 3 now...we'll see if customer wants to pay difference for larger conduit, extra cables, etc.. . Unfortunately, they insist on floor stubbed feeds as they do not want any power poles in the open room...
  7. vegasnortel

    Conduit size recommendations

    Can you help me with my request for the correct conduit size for the electrician? I need (24) Cat5e's to feed into a 8 workstation group(3 each), of modular furniture stubbing up from the floor. Where can I find a chart or formula for this? Thanks!
  8. vegasnortel

    Price "per drop" survey info requested - Thanks guys!!

    Hawks, Thanks for the tip! That is a SMOKING price on bulk! If I get the bid, I will probably buy from them and report back to all. At that price, I would pre-measure every run and cut to length. Thanks again all! Rich
  9. vegasnortel

    Price "per drop" survey info requested - Thanks guys!!

    Thanks all! I had a $350 per drop figure in my head before even asking...thanks for validation. I agree....sounding a little like a pain with many triples going to modular furniture, etc..., but work is work and if it is profitable I will take it! Thanks again guys! Have a great day! Rich
  10. vegasnortel

    Price "per drop" survey info requested - Thanks guys!!

    Sorry Bob...thanks for pointing out: Each voice station cable will consist of one (1) 4 pair, 24 AWG, Category 6, 550 MHz Systimax GigaSPEED #2071 CMP, UTP cable, continuous cable run (no splicing) from the new IDF (Intermediate Distribution Frame) to the work-station. At the work-station...
  11. vegasnortel

    Price "per drop" survey info requested - Thanks guys!!

    Can anyone tell me what they would charge in thier market per run for the following: Each data station cable will consist of two (2) 4 pair, 24 AWG, Category 6, 550 MHz Systimax GigaSPEED #2071 CMP, UTP cable, continuous cable run (no splicing) from the new IDF (Intermediate Distribution Frame)...
  12. vegasnortel

    Nortel Key Lamp Module 48 Button

    thanks for all your help, Just to clarify rg11 jack pin out 1&4 power, 2&3 line from PBX Cat 5 module 4&5 line, 3&6 power from VP324 3 Positive 6 Negative Could of already burded out if it was reversed?
  13. vegasnortel

    Nortel Key Lamp Module 48 Button

    NO actualy is 3 and 6 on cat 5 module
  14. vegasnortel

    Nortel Key Lamp Module 48 Button

    vp 324 gets hot and not lighting up the module,Any suggestion? patched to 5 and 6 on the cat 5 jack
  15. vegasnortel

    Silent Monitor on Outbound for Call Center BCM400

    thanks Dewey. Also, will there be any meaningful reports for the supervisor for agent activity on outbound calls. I have already informed customer that the call center is designed for inbout, ACD/UCD functionality, queing (always spell wrong!), etc.. The Monitoring is very important, but will...

Part and Inventory Search

Back
Top