Hi, I have this strange problem when trying to set up new IP sets.
If I try to connect them to the same LAN as the SS is on,
it gets all the IP-setup it needs from the DHCP-server, and I put
in the IP-address of the SS manualy.
The set will then reboot and try to connect to the SS, but fails...
Hi anybody know if it's possible to connect one
of these old shelfs to the new G6 servers?
I know there are HBA's,
but we need hardware RAID-controller that connects to
these old SCSI units.
Can't seem to find any.
Hi have new Rls5.5 install with a strange FNA problem.
For some reason a set with CLS=FND calls are CFNA after
the RCO spesified number of rings, while a set with
CLS=FNA just keeps ringing and ringing.
Thought it was supposed to be the opposite way....
>ld 21
PT1000
REQ: prt
TYPE: rdr
TYPE...
A few months back we upgraded our Opt.11c from Rls4.5 to Rls5.0
after this we are not able to get our two DCH's to work simultaneously.
I can only program one DCH and get it up and running.
If i program DCH 8 first on port 1 of the SDI/DCH-card,
it works fine, DCH established.
When I then try to...
Hi
I'm new in this job that includes maintaining a Server running BE8.6
backing up both external servers via WAN and local servers via FC-AL fiber-loop.
But I can't find anywhere how it's defined that a backupjob
for a local server should use the fiber-loop, while a remote
backupjob should use...
Congratulations acewarlock on being voted TipMaster of the Week by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!
Congratulations!!!
Well deserved :-)
Hi.
The Tapedrive in the old Mermail is defective, and I need to replace it.
Drive is an old SLR-type, marked 150MB.
Think it's a MM8, and it sits in an IDE-shelf.
Can I replace it without powering down the whole mailsystem?
It's a single mail, no shadowing. Just one tape and one harddrive.
Not...
Hi.
We have paging setup so that DID-calls when not answered,
is forwarded to radio-paging system with
FDN 88 , 88 is FFC-code RPAX
Paging system is configured with "Meet me" so the paged
individual dials FFC-code 89 RPAN to pick up the call.
Problem is that if nobody picks up the call, it...
Hi, I try changing from the default password on an Opt11c. Rls.4.5
But when I try logi, I only get OVL428. Both on admin1 and admin2.
If I change only admin2 password and leave admin1 default,
I get OVL428 on the admin2 pwd, but I can logi with admin1.
Funny thing is it rejects the pwd at logi...
Hi, I'm trying to make an expect-script that telnets
into a host, and extracts data from it into a file.
I have the script up and running, sort of...
It outputs the info into the file, but without any "timestamp".
I'd like to use the date command to put the time into
the same file with the rest...
Hi.
Just wanted to know if it's possible to set up
a passtrough way in to the MIRAN2.
So I can use the AX-function to access MIRAN
just like with the MerMail.
And can it be done without connecting the MIRAN serial-cabel
to a TTY-port?
Thanks :-)
Hi, I need some pointers on how to accomplish this:
In a landscape of ca. 20 M3904 we want the phones to ring
only 1 ore 2 times, then go silent, only with the lamp on
the phone flashing, until answered.
How can we do that?
Sets are equiped with headsets too.
I know if I leave the handset of...
Hi, need some pointers on a short AWK-script please.
I have 2 files, one large file looking something like this:
# File header bla bla
# more headertext here
firstword * 5
secondword *
anotherword 0 15
hello
and *
so-on *
The second file looks like this:
anewword
another-word
goodbye
test
I...
The documentation says PS only runs on XP and W2003,
and a Vista-version is on the way.
But, what about us who have to use W2K???
Can we use any of those?
Just wondering what program you use to connect to your switches.
I for myself use Procomm 4.8 , but it's no longer developed any further by Symantec if I understand them right....
So, what programs are there, (apart from OTM, EM etc) and what's the pro's and con's with them?
:-)
Hi.
First, I'v learned alot from this forum, thanks guys :-)
But there's one thing I haven't found an answer to.
I'm making a 'small' script to transfer a list off text-files. The files have tab-delimited text, but when the receiver gets the files, the tabs have been replaced with 8 spaces.
I...
Hi, I'm new to AWK and trying to parse through a long list of records and extract fields from them.
sample record:
DN 0
TYPE CDP
STCD TSC
DN 2203
CPND
CPND_LANG ROMAN
NAME
XPLN 27
DISPLAY_FMT FIRST,LAST
TYPE 500
TN 008 0 09 02 MARP DES SAS...
Hi, am trying to print system messages on an Opt11, rls4.50
but I'm only getting:
OVL448 System message lookup is temporarily unavailable.
Wait 30 seconds and repeat request.
Have been like this for a long time now....
Am I missing a file on the switch with the messages, or something?
:-)
Hi, I'm having a problem with a Opt.11c Mini that sometimes (2-3 times pr year) locks up all callhandling in the expansion-chassis.
The exp-chassis holds the Dect-system(DMC-8 + DMC-4) and MerMail(MM-13).
Switch is on Rls. 25.15
Thought it could have someting to do with system resources, so i...
Hi, I'm trying to program a 3903-set with a Hotline-key on key 0, and with a name on the line, so that the name show's up on the receiving side when the hotline in activated.
How do I go about doing this?
Can't se any way of defining a name without an extension DN, but where shall I put the...