Hey guys, I have a client who had cabling installed, believe it or not, behind 4-5 electric baseboard 3-4' heaters, some of which may be 347v.... Not one or two, but a whole bundle.... I am going to recable because they have so many connection issues, but I have to write a letter for them to be...
Hey guys, really stupid question, especially concidering I have been working on theese things for 10 years, but I'v never had to do this....
What is the procedure to remove 2 12x0's off of a MICS system 4.1 with a PRI without trashing all of the programming. I yanked a fiber card once, and had...
Hey everyone, has anyone ever installed a smdr6 module on a BCM 400... I have a serial only application and the BCM IP only output is no help...
Thanks!
Hey everyone, just moved a client's CP 100 from the CICS ver 4.1 to a new MICS with a slightly used 6.1 non-xc software. Now, I will admit that I have put it on a different DN, and I am programming the MICS from sctatch, but the thing just wont come back up, doesn't show up in the maintenance...
Hey everyone, I am a bit of a merlin newbie.... I am working on a Release 3 processor with a bunch of MLX 10's and a single MLX 20. The problem is theat the MLX 20, ext 100, 1st port, doesn't offer me the ability to log into the system to make programming changes. I read in the manual that the...
Hi Everyone, I deparately need a copy of the bulletin that Nortel in regards to the bad capacitors on the man board of the BCM 200's and 400's, and the replacement.
My client is getting hosed by his last vendor, who didn't replace it under recall, and refuses to pay for the new board, even...
Hi!
I have a spare 1841 lying around...Is it possible to bridge the two interfaces together and use the firewall in between them for some basic filtering between a potentially malicious server that has to be on the same subnet as the rest of the LAN...eg
server NIC --->FE0/0 on 1841 -->...
Hey all!
I have a brand new Catalyst 3750 at a client's place, we have 10 & 100mb LAN extensions to different offices that have been subnetted to different 10.0.x.x subnets...four in total.
We added one recently that directly over the LAN Extention...the thin client was pinging at 62ms over...
Hey all...
i cant seem to attach to the shared volumes after enabling sharing on them.
I do get the prompt for the username and password when i attach to them from a windows PC, but i don't know the default username or PW...and i tried all of the ones in the system...
Any ideas?
Thanks!
Hey all...
just put in a brand new 3750, and did the express setup...works great until I change the IP addy for the mangement interface...even after I change the IP on the local PC that I'm using to the same subnet...It doesn't respond.
Checked the running config , and ip http server is there...
Hey guys,
I need a way to forward calls comming in from a DID number to 2 external numbers at the same time....if possible. Is it possible? Got lots of avaliable outbound trunks on our PRI's....
Thanks!
I have a network that is linked by a bunch of of ATM over fiber links, essentially 100 an 10mb ethernet extensions.
The problem is the 3 locations are out of ip addresses, so it's time to route and subnet. The locations are as follows: A and B have a 100mb fiber, and A to C has 10mb fiber, we...
Hey everyone,
was just at a client office where we took over maintenance of a CP100 rls 3.1 on a CICS....it was used about 6 months ago then disabled beacuse nobody knew how to use it, now they wan it back on line, so I brought it back up, and the sound is completely GARBLED from any port or...
Boy is this going to sound dumb, but I am just getting started on Cisco s, so please bear with me:
I have two networks, separated by an 1800 series router , config below.... from a workstation on either side, I can ping the local subnet interface, the other subnet interface, but nothing on the...
Hey everyone,
I have a client with three locations: head office to Branch 1 has a 100mb full duplex ATM circuit, terminated to ethernet, and Branch 2 has a 10mb full duplex ATM terminated to Ethernet, as well as a 10mb full duplex ATM terminated to Ethernet between Branch 1 and 2. Now I know...
Hi everyone,
my clients BCM 400 is down...the RAM has been checked and changed, the Hard Drive was tested, read ,scandisked on a PC, so that's fine.....no go on it though...the lights just keep flashing on the front of the unit.....What should I do next???? The MSC and DTI are still running...
Hi everyone,
I am going to swap a client's 4x0 trunk module for a 0x32 station module on a BCM 400, and I think it's pretty starightforward, but I was wondering if there are any important steps that I should know....
Thanks!
-t-
Trevor Farren
Metrotech Telecom Inc.
Hi guys,
we are a Montreal office who needs compentent tech for some work in Richmond, BC. I know we're not supposed to post stuff like this, but I am desparate.....please DO NOT respond in the forum....contact me at "info at metrotech dot ca"
Thx
Trevor Farren
Metrotech Telecom Inc.
Hey everyone....I am doing a large expansion of a client system. Went from a MICS cab alone, added for 0x16, an asm, and a 12x0 all on a 6-port fiber card the MICS is a ver 7.1 XC. Boots up kinda, most sets showing "In Maintenance", got a code 60 on port 101-dn 100, can't get into maintenence...