Hi,
We've got a customer with some W2008 activation problems.
Some time ago another supplier sold them a W2008 server, and the supplier installed it with their own activation key, because the customer didn't have any Windows license left.
Now this server keeps telling that Windows is not...
Hi.
A customer has got a Power 720 (8202-E4B) with internal DVD and tape units.
He's got 3 lpars, and wants to dlpar internal dvd and tape from one lpar to another.
It seems that the dvd and tape hang from U78AA.001.XXXXXXX-P1-T9 (RAID Controller), that should only manage dvd and tape (no...
Hi all.
We've just received a NetBackup Appliance (52XX I think), and I've been asked to redirect all the logs to syslog, so it can be forwarded to AlienVault OSSIM.
I've gone thru the documentation and I've googled around, but I don't find an example on how to redirect the logs.
I've found...
Hi, I'm not a DBA, I'm an AIX admin, so excuse me if there are mistakes.
In a client they're trying to install Oracle 11.2.03 (Oracle + SAP Portal on AIX 6.1 TL07).
They've executed the prerequisite checks, and they've told me that it is complaining about 2 AIX apars not being installed...
Hi, we have some performance issues starting SAP Portal on AIX 6.1 TL5 SP6.
It takes more than 10 minutes to start, and there is a jlaunch process with high CPU and PgSp values in topas for more than 10 minutes.
It is a Power7 LPAR (0'39 CPU, 1 virtual cpu, 16GB RAM, SMT on). I've also tried...
Hi,
I'm not very used to HP-UX, so I don't know if I've done a mistake or not.
And sorry for my poor english.
We've got a BL860c i2, with HP-UX 11.31.
There are several luns (HP EVA) assigned and used, but there was also a temporary lun that is no longer in use.
They asked me to deassign and...
Hi, I've read somewhere that in short we will be able to manage power blades (PS70X) from a HMC.
¿Does anybody knows something about this? ¿Is there any documentation available?
I've searched in google, in IBM page and in redbooks but I haven't seen anything, except an IBM statement of direction...
Hi,
I've got a Power6 server with redundant VIOs, and I've had to reinstall one of the VIOs.
Everything is OK, except I would like to create some dummy hdisks, because in the other VIO there are some gaps in the hdisks names (hdisks that were present but have been deleted), and I would like...
Hi,
We've got a client where they currently have HP-UX, and they are planning to migrate to Linux (mainly Red Hat but Suse is OK also).
Right now they've got a cluster (Serviceguard), with main node on a physical server, and passive node on a virtualized server (Integrity Virtual Machine)...
Hi, I was wondering if this is feasible. On a LPAR (disks virtualized with dual VIOs) I need to mirror a VG and split the mirror. Then I need to remove the hdisks with the splitted copy, remove the mapping from the VIOs and remap this disks to a new LPAR.
Then on this new LPAR I will varyon the...
Hi,
I need to setup a new LPAR (AIX 6.1) with same groups and users as other existing LPARS. It's a new SAP dialog instance server that needs to NFS mount some directories from existing SAP server, so users UIDs and groups GIDs must match.
The problem is in this new LPAR sshd group has GID...
Hi,
We've got some Power6 550 servers, with dual vio, connected to a HP EVA 8400. I've installed the AIX MPIO ODM Kit for EVA, and everything worked fine. Using /opt/hphsv/bin/hsvpahts we could see all the hdisks, and their paths (8 paths for each lun).
Now, our storage staff has eliminated 2...
Hi,
I'm trying to setup some windows shares, and mount them from my hp-ux 11.31 boxes.
It works fine if I share the windows directories with a local user account, but it doesn't work when I try it with domain users.
What I'm doing is:
- share a windows directory
- mkdir a mount point
-...
Hi,
We are in the process of migrating a client's AIX servers, from CLARiiON to Symmetrix VMax.
An EMC engineer came to "help" us with the migration, but I've seen something strange.
On a HACMP cluster he didn't change the reserve_policy parameter on the hdiskpower devices, before using them...
Hi,
A client has got a 2 node cluster (AIX 5.3, HACMP 5.4) and they want to clone one of the nodes, to build a test LPAR.
They want to clone rootvg from one of the nodes with alt_disk_copy, and then create a new LPAR with this rootvg. This new LPAR will NOT be part of any cluster.
Does the...
Hi, I've been asked to increase the queue_depth parameter for some virtualized hdisks in a HACMP cluster.
My question is about queue_depth value on the clients and on the VIOs.
If queue_depth is 8 on the VIOs can I set queue_depth to 8 also in the LPARs, or should I set a lower value?
The...
Hi, we've got an application running in a tomcat on an AIX server, that needs to connect to another application using https. We need to add the CA certificate, in order to trust the other application.
Where do I need to install/add the certificate in the AIX server?
Thank you
Hello,
We have a Debian server with GLPI installed (servidesk.my.dom). It was working fine until this morning.
We have migrated our mail from an external provider to Exchange, so we wanted GLPI to send notification thru the new Exchange server (mail.my.dom).
I don't know who has done what, but...
Hi,
I'm new to HP-UX, and I'm going to install some BL860 with HP-UX 11i v3.
In one of the blades we are going to create some Virtual Machines, also with HP-UX 11i v3.
I'm reading some documentation, but there is one thing I've not found, about SAN storage access from the VM guests.
If there...
Hi, I've got some servers that show that old_rootvg exist (when issuing lsvg), but when I do lspv there is no hdisk associated with it.
I didn't install these servers, so I don't know what happened, but I suppose someone did an alt_disk_install/alt_disk_mksysb and rebooted from the new...